2.2.1
Last Modified: Monday, December 04, 2006 at 06:20 PM
| Correction | short description | link (click) |
|---|---|---|
| EN220CE126 | Only the first 40 entries in ENVIRONMENT/STAGE/SYSTEM table are recognized when using TPI. Replaces fix for EN220CE092! | download EN220CE126.ZIP |
| EN220CE127 | Stage
number is not validated, no selection list is shown for TPI MOVE and
DELETE actions; I0902 “Invalid Action” with TPI GENERATE, MOVE and DELETE actions when 1) ENTER and then 2) PF3 is pressed. |
download EN220CE127.ZIP |
| EN221CE134 OPTIONAL |
In case of CAT/STOW errors during GENERATE, E/NAT does not show the variable parts of error messages. | download EN221CE134.ZIP |
| EN221CE135 | PREDICT commands in batch do not work in case the PREDICT ID is longer than 22 characters. With PREDICT 3.4.1 the result is a "CATASTROPHIC ERROR" 1106 ("Data string for input field too long.") in line 0940 of program BATOB1. | download EN221CE135.ZIP |
| EN212CE136 | Impossible to perform actions on PREDICT objects of types other than FI. | download EN212CE136.ZIP |
| EN212CE138 | NAT1512 in EN9801M with NATURAL 2.3.4 and NATURAL 3.1.2 | |
| EN221CE139 Preliminary |
When executing a LOGON command within a COMMAND NATURAL in a processor, E/NAT loops. | download EN221CE139.ZIP |
| EN221CE140 | When pressing PF12 on the E/NAT TPI ADD panel, E/NAT goes back to the CA-Endevor actions selection menu instead of showing the TYPE selection menu. | download EN221CE140.ZIP |
| EN221CE141 | NAT0886 during Generate of large source even if ESIZE>96 specified in NATURAL parameter module. | Details |
| EN221CE147 | The entry of a generic TYPE ("X*") on the TPI ADD panel shows a TYPE selection list, no chance to do a generic specification (e.g. NAT*). | download EN221CE147.ZIP |
| EN221CE149 OPTIONAL |
Show a popup window in case the JCL/SCL was submitted. | download EN221CE149.ZIP |
| EN221CE160 | When ADDing via TPI, the default value of FROM MEMBER is "*". This could cause that all members are added when DISPLAY LIST is set to "N" even if one specific ELEMENT was entered. | download EN221CE160.ZIP |
| EN221CE163 | The entry of a stage number on the TPI GENERATE panel is not recognized. | download EN221CE163.ZIP |
| EN221CE166 | Backout/Backin actions sometimes fail with error code I0612. | download EN221CE166.ZIP |
| EN221CE169 | Abend 0C1 when CONAPI step is included in the E/NAT processor. | download EN221003.TXT |
| EN221CE170 | Entry of valid characters for element names not verified with ADD action when user is prompted to enter a short element name. | download EN221CE170.ZIP |
| EN221CE175 OPTIONAL |
Allow definition of FUSER/FDIC file numbers >255. | download EN221CE175.ZIP |
| EN221CE176 | BSTPPARS: E004 INVALID COMMAND WORDING in case CCID contains blanks. | download EN221CE176.ZIP |
| EN221CE177 | Avoid that user overwrites COMMENT in case CCID is required when the corresponding prompt appears (RETRIEVE action). | download EN221006.TXT |
| EN221CE180 | Several problems with MCT member selection list corrected. | download EN221CE180.ZIP |
| EN221CE181 | FDIC setting not recognized
with NATURAL 3.x. Reason: NATURAL now resets the FDIC setting to the
initial values each time a LOGON is executed. Source change in EN9471X. |
download EN221CE181.ZIP |
| EN221CE193 |
User RC 7101 from Userexit 71 during RETRIEVE of a PREDICT verification. |
download EN221CE193.ZIP |
| EN221CE197 | Updates required to use E/NAT 2.2.1 together with AllFusion Endevor Release 4.0. | download EN221CE197.ZIP |
| EN221CE200 | NAT1308 in EN9200M in case of long variable message parts (e.g. DDM-Name). | download EN221CE200.ZIP |
| EN221CE201 | E/NAT does not process PREDICT 4.3.x objects | download EN221CE201.ZIP |
| EN221CE202 | Endevor 4.0 SP2: A SET STOPRC field was added to panels. Update for E/NAT panels. | download EN221CE202.ZIP |
| EN221CE203 | Package processing for SYSERR message texts fails with I0664 (Inconsistency) in case the error texts are very long. | download EN221CE203.ZIP |
| EN221CE204 | Not possible to leave field level help display when browsing all map fields after help was invoked using PF1. | download EN221CE204.ZIP |
| EN221CE206 | When using GLOBAL TYPE SEQUENCING with Endevor r7, the function 4.N (Modify Defaults for E/NAT) is not available. | download EN221011.ZIP |
| EN221CE207 | Verify uniqueness of type definitions in 4.N.1. | download EN221CE207.ZIP |
| EN221CE208 | LDA lines longer than 100 bytes are truncated with NATURAL 4.1. | download EN221CE208.ZIP |
| EN221011 | Support Global Type Sequencing with Endevor r7. | download EN221011.ZIP |
| EN221CE209 | References to Subroutines not deleted in target environment during GENERATE / MOVE. Problem arises with NATURAL 4. | download EN221CE209.ZIP |
| EN221CE210 | Long PREDICT member names (>10 chars) are truncated in case option Include PREDICT XREF is set to “F” on ADD panel. | download EN221CE210.ZIP |
| EN221CE211 | Prevent from adding duplicate Element names for the same member name. | download EN221CE211.ZIP |
| EN221012 | Accept NATURAL RC1 in E/NAT exit for non-NATURAL types. Suppress NAT9987 message. | download EN221012u.TXT |
| Problem # | ||
| EN220CE126 | Description: | Only the first 40 entries in ENVIRONMENT/STAGE/SYSTEM table are recognized |
| Cause: | Coding problem. | |
| Solution: | Download and apply correction EN220CE126.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.0 and E/NAT
2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN220CE126.LOG
for verification of success. The fix is loaded into library ENV222 member EN7901M. (1) Copy EN7901M from library ENV222 to library EN and (2) distribute the new module to all libraries EN in all FUSERs used. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN220CE127 | Description: | Problems with TPI GENERATE/MOVE/DELETE actions |
| Cause: | Coding problem. | |
| Solution: | Download and apply correction EN220CE127.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.0 and E/NAT
2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN220CE127.LOG
for verification of success. The fix is loaded into library EN members EN7120M, EN7140M, EN7150M, and EN7160M. Distribute the new modules to all libraries EN in all FUSERs used. Please re-apply fix EN221CE140 after this fix was applied! To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE134 OPTIONAL |
Description: | In case of CAT/STOW errors during GENERATE, E/NAT does not show the variable parts of error messages. |
| Cause: | The variable parts (:1:, :2: and so on) of system error messages are not replaced before displaying the error message. | |
| Solution: | Download and apply correction EN221CE134.ZIP
(zipped, see above). This correction applies to E/NAT 2.1.2, E/NAT
2.2.0, and E/NAT 2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE134.LOG
for verification of success. The fix is loaded into library EN member EN9200M. (1) Save the existing module EN9200M in a library not used with E/NAT. (2) Copy the module USR2009N from library SYSEXT to library SYSTEM on all FUSERs used (see E/NAT Installation Manual chapter "Setting up NATURAL and NATURAL Security" for details). (3) Load the fix using the ENIFIX utility (see Technical Note 006 for details). (4) Distribute the new module EN9200M to all libraries EN in all FUSERs used. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE135 | Description: | PREDICT
commands in batch do not work in case the PREDICT ID is longer than 22
characters. With PREDICT 3.4.1 the result is a "CATASTROPHIC ERROR" 1106 ("Data string for input field too long.") in line 0940 of program BATOB1. |
| Cause: | PREDICT limits the maximum length of the command to 72 characters. This limit is exceeded when the ID is too long. | |
| Solution: | Download and apply correction EN221CE135.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.0 and E/NAT
2.2.1 only. Please download and unzip the file. Save your existing
member EN9471X in library EN. Then transfer it to the host (with
conversion from ASCII to EBCDIC) and load it using the SYSTRANS utility
of NATURAL. SYSTRANS will load the source of user exit 71 (member
EN9471X) into library EN. If necessary, adapt the user exit, then STOW
it. Distribute the new module to all libraries EN in all FUSERs used. |
|
| EN212CE136 | Description: | Impossible to perform actions on PREDICT objects of types other than FI. |
| Cause: | Coding problem. | |
| Solution: | Download and apply correction EN212CE136.ZIP
(zipped, see above). This correction applies to E/NAT 2.1.2, E/NAT
2.2.0, and E/NAT 2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN212CE136.LOG
for verification of success. The fix is loaded into library EN members EN2021M and EN2041M. (1) Load the member to library EN using the ENIFIX utility and (2) distribute the new module to all libraries EN in all FUSERs used. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN212CE138 | Description: | NAT1512 in EN9801M with NATURAL 2.3.4 and NATURAL 3.1.2 |
| Cause: | Newer NATURAL versions work different. | |
| Solution: | Change the BLKSIZE parameter of CMWKF04 in ENATJCL and NDVLDEF from 23476 to 32760. | |
| EN221CE139 | Description: | When executing a LOGON command within a COMMAND NATURAL in a processor, E/NAT loops (endless execution of the command specified). No way to re-invoke E/NAT processing. |
| Cause: | In the target library the saved GDA contents was overwritten with empty data. EN1091M, EN9801M and EN9993L corrected. | |
| Preliminary | Solution: | Download and apply correction EN221CE139.ZIP
(zipped, see above). This correction applies to E/NAT 2.1.2, E/NAT
2.2.0, and E/NAT 2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE139.LOG
for verification of success. The fix is loaded into library EN members EN1091M, EN9801M, and EN9993L. (1) Load the members to library EN using the ENIFIX utility and (2) distribute the new module to all libraries EN in all FUSERs used. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
| EN221CE140 | Description: | When pressing PF12 on the E/NAT TPI ADD panel, E/NAT goes back to the CA-Endevor actions selection menu instead of showing the TYPE selection menu. |
| Cause: | Coding problem. EN7120M corrected. | |
| Solution: | Download and apply correction EN221CE140.ZIP
(zipped, see above). This correction applies to E/NAT 2.1.2, E/NAT
2.2.0, and E/NAT 2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE140.LOG
for verification of success. The fix is loaded into library EN member EN7120M. (1) Load the member to library EN using the ENIFIX utility and (2) distribute the new module to all libraries EN in all FUSERs used. Do NOT apply fix EN220CE127 after this fix was applied! To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE141 | Description: | NAT0886 during Generate of large source even if ESIZE=128 specified in NATURAL parameter module. |
| Cause: | ESIZE parameter in EN002#U sets a fix ESIZE of 96KB. | |
| Solution: | Bypass: Specify ESIZE parameter in ENDEFLTS and in panel 4.N.2 (DYNBAT/DYNONL). | |
| EN221CE147 | Description: | The entry of a generic TYPE ("X*") on the TPI ADD panel shows a TYPE selection list, no chance to do a generic specification (e.g. NAT*). |
| Cause: | Coding problem. EN7120M corrected. | |
| Solution: | Download and apply correction EN221CE147.ZIP
(zipped, see above). This correction applies to E/NAT 2.1.2, E/NAT
2.2.0, and E/NAT 2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE147.LOG
for verification of success. The fix is loaded into library EN member EN7120M. (1) Load the member to library EN using the ENIFIX utility and (2) distribute the new module to all libraries EN in all FUSERs used. Do NOT apply fix EN220CE127, or EN221CE140 after this fix was applied! To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE149 OPTIONAL |
Description: | Show a popup window in case the JCL/SCL was submitted. |
| Cause: | ||
| Solution: | Download and apply correction EN221CE149.ZIP
(zipped, see above). This correction applies to E/NAT 2.1.2, E/NAT
2.2.0, and E/NAT 2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE149.LOG
for verification of success. The fix is loaded into library EN member EN9306M. (1) Load the member to library EN using the ENIFIX utility and (2) distribute the new module to all libraries EN in all FUSERs used. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE160 | Description: | When ADDing via TPI, the default value of FROM MEMBER is "*". This could cause that all members are added when DISPLAY LIST is set to "N" even if one specific ELEMENT was entered. |
| Cause: | Default value of field FROM MEMBER is set to "*". EN0110M and EN7120M corrected. | |
| Solution: | Download and apply correction EN221CE160.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.0, and E/NAT
2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE160.LOG
for verification of success. The fix is loaded into library EN members EN0110M, EN7120M. (1) Load the members to library EN using the ENIFIX utility and (2) distribute the new modules to all libraries EN in all FUSERs used. Do NOT apply fix EN220CE127, EN221CE140, or EN221CE147 after this fix was applied! To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE163 | Description: | The entry of a stage number on the TPI GENERATE panel is not recognized. |
| Cause: | Coding problem. EN7140M corrected, EN7141M1 updated. | |
| Solution: | Download and apply correction EN221CE163.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.0, and E/NAT
2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE163.LOG
for verification of success. The fix is loaded into library EN members EN7140M, EN7141M1. (1) Load the members to library EN using the ENIFIX utility and (2) distribute the new modules to all libraries EN in all FUSERs used. Do NOT apply fix EN220CE127 after this fix was applied! To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE166 | Description: | Backout/Backin actions sometimes fail with error code I0612. |
| Cause: | USR0341N is not able to flush objects located in the NATURAL buffer pool in case the age is less than 30 minutes. In such a situation RC=3 is returned by USR0341N and the action fails. | |
| Solution: | Download and apply correction EN221CE166.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.0, and E/NAT
2.2.1 only. Please download Technical
Note 006 to see how to use the ENIFIX utility
provided with E/NAT. Download and read the text file EN221CE166.LOG
for verification of success. The fix is loaded into library EN member EN1013M. (1) Save to old member EN1013M by copying it to a different (unused) NATURAL library. (2) Copy module USR0340N from library SYSEXT to library SYSTEM on all FUSERs used (see E/NAT 2.2.1 Installation Manual for more details about how to copy the USR* modules from library SYSEXT to library SYSTEM). (3) Optional: remove USR0341N from library SYSTEM on all FUSERs in case this module is not required by any other application. (4) Load the corrected member to library EN using the ENIFIX utility and (5) distribute the new module to all libraries EN in all FUSERs used. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
| EN221CE169 | Description: | Abend 0C1 when CONAPI step is included in the E/NAT processor. |
| Cause: | When the E/NAT processor step executing EN004#U is preceded by the CONAPI utility, EN004#U cannot find module EN007#U. | |
| Solution: | Download and apply correction EN221003.TXT.
This correction applies to E/NAT 2.2.1 only. This PTF reloads EN007#U. |
|
| EN221CE170 | Description: | Entry of valid characters for element names not verified with ADD action when user is prompted to enter a short element name. |
| Cause: | Element name not verified after user entry. | |
| Solution: | Download and apply correction EN221CE170.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE170.LOG
for verification of success. The fix is loaded into library EN (1 member, see log). (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE175 OPTIONAL |
Description: | Allow definition of FUSER/FDIC file numbers >255. |
| Cause: | Several verifications ensure that no FUSER or FDIC file number greater than 255 can be defined (requirement of NATURAL 2.2 and earlier). | |
| Solution: | Download and apply correction EN221CE175.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE175.LOG
for verification of success. The fix is loaded into library EN (7 members, see log). (1) Copy the existing members to any library not used by E/NAT (2) Load the members to library EN using the ENIFIX utility and (3) distribute the new modules to all libraries EN in all FUSERs used. Note: This fix allows the definition of FUSER/FDIC file numbers up to 999. Do not apply the fix in case you still use FUSER/FDIC file numbers less or equal 255. Do not rename the old members but copy them as described. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE176 | Description: | BSTPPARS: E004 INVALID COMMAND WORDING in case CCID contains blanks. |
| Cause: | CCID was not embedded in apostrophes. In case CCID contains a blank character, the second part was interpreted as a token. | |
| Solution: | Download and apply correction EN221CE176.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE176.LOG
for verification of success. The fix is loaded into library EN member EN9300M. (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old member but copy it as described. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE177 | Description: | Avoid that user overwrites COMMENT in case CCID is required when the corresponding prompt appears (RETRIEVE action). |
| Cause: | COMMENT not protected on panel. | |
| Solution: | Download and apply correction EN221006.TXT.
This correction applies to E/NAT 2.2.1 only. In case CCID is required, but not entered on RETRIEVE, this panel is called by CA-ENDEVOR. It prompts the user to enter CCID and/or COMMENT. In case of NATURAL elements the COMMENT is defined by E/NAT and carries information about the member to be retrieved. Thus it may not be modified and is suppressed in this modification. |
|
| EN221CE180 | Description: | Several problems with MCT member selection list corrected. |
| Cause: | Coding problem. EN0061M corrected. | |
| Solution: | Download and apply correction EN221CE180.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE180.LOG
for verification of success. The fix is loaded into library EN member EN0061M. (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old member but copy it as described. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE181 | Description: | FDIC setting not recognized with NATURAL 3.x. |
| Cause: | NATURAL now resets the FDIC setting to the initial values each time a LOGON is executed. | |
| Solution: | Download and apply correction EN221CE181.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE181.LOG
for verification of success. The fix loads the new member EN9982 into library EN and the member EN9997Z into library SYSTEM. (1) Copy the existing member to any library not used by E/NAT (2) Load the members to library EN and SYSTEM using the ENIFIX utility and (3) Distribute the new module to all libraries EN and SYSTEM in all FUSERs used. (4) Adapt user exit EN9471X as specified in text file EN221CE181.TXT located in EN221CE181.ZIP. (5) Distribute the adapted module EN9471X to all libraries EN in all FUSERs used. Note: Do not rename the old members but copy them as described. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE193 | Description: | User RC 7101 from Userexit 71 during RETRIEVE of a PREDICT verification. |
| Cause: | Coding problem. EN2022M corrected. | |
| Solution: | Download and apply correction EN221CE193.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE193.LOG
for verification of success. The fix is loaded into library EN member EN2022M. (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old member but copy it as described. To view the Technical Note you will need Adobe Acrobat Reader 3.0 (see Downloads for free download from Adobe's Website). |
|
| EN221CE197 | Description: | Updates required to use E/NAT 2.2.1 together with AllFusion Endevor Release 4.0. |
| Cause: | New Endevor release. | |
| Solution: | Download and apply correction EN221CE197.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1 with
AllFusion Endevor release 4.0 only. Please download the ZIP file and
carefully read the file readme.txt for details. This fix is always required when using E/NAT 2.2.1 together with Endevor 4.x (upgrade or first time install)! |
|
| EN221CE200 | Description: | NAT1308 in EN9200M in case of long variable message parts (e.g. DDM-Name). |
| Cause: | Coding problem. EN9200M corrected. | |
| Solution: | Download and apply correction
EN221CE200.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE200.LOG
for verification of success. The fix is loaded into library EN member EN9200M. (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old member but copy it as described. To view the Technical Note you will need Adobe Acrobat Reader (see Downloads for free download from Adobe's Website). |
|
| EN221CE201 | Description: | E/NAT does not process PREDICT 4.3.x objects |
| Cause: | PREDICT system file layout has changed. EN0110M, EN0124M, EN2000M, EN2008M, EN2040M, EN2041M, EN2042M, EN2045M corrected. | |
| Solution: | Download and apply correction
EN221CE201.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE201.LOG
for verification of success. The fix is loaded into library EN, 8 members as listed above. (1) Copy the existing members to any library not used by E/NAT (2) Load the updated members to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old members but copy them as described. To view the Technical Note you will need Adobe Acrobat Reader (see Downloads for free download from Adobe's Website). |
|
| EN221CE202 | Description: | Endevor 4.0 SP2: A SET STOPRC field was added to panels. Update for E/NAT panels. |
| Cause: | Panel update to Endevor 4.0 SP2. Panels C1SB0000 and C1SP2000 corrected. | |
| Solution: | Download and apply correction
EN221CE202.ZIP.
This correction applies to E/NAT 2.2.1 only. Please read the file readme.txt for further instructions. The file is part of the ZIP file. The following panels will be updated: - C1SB0000 - Batch Options Menu - C1SP2000 - CREATE/MODIFY PACKAGE. |
|
| EN221CE203 | Description: | Package processing for SYSERR message texts fails with I0664 (Inconsistency) in case the error texts are very long. |
| Cause: | Coding problem. EN1044M corrected. | |
| Solution: | Download and apply correction
EN221CE203.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE203.LOG
for verification of success. The fix is loaded into library EN member EN1044M. (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old member but copy it as described. To view the Technical Note you will need Adobe Acrobat Reader (see Downloads for free download from Adobe's Website). |
|
| EN221CE204 | Description: | Not possible to leave field level help display when browsing all map fields after help was invoked using PF1. |
| Cause: | Coding problem. EN9100H corrected. | |
| Solution: | Download and apply correction
EN221CE204.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE204.LOG
for verification of success. The fix is loaded into library EN member EN9100H. (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old member but copy it as described. To view the Technical Note you will need Adobe Acrobat Reader (see Downloads for free download from Adobe's Website). |
|
| EN221CE206 | Description: | When using GLOBAL TYPE SEQUENCING with Endevor r7, the function 4.N (Modify Defaults for E/NAT) is not available. |
| Cause: | When using GLOBAL TYPE SEQUENCING with Endevor r7, the function N for "NATURAL - Modify Defaults for ENDEVOR/NATURAL-Interface" is not available. Thus the user cannot set the E/NAT Defaults. | |
| Solution: | Download and apply correction
EN221011.ZIP.
This correction applies to E/NAT 2.2.1 only. Upload the file C1SE001.PAN as attached into library ENPRFX.ENATvvv.ISPPLIB in BINARY MODE. |
|
| EN221CE207 | Description: | Verify uniqueness of type definitions in 4.N.1 |
| Cause: | Coding problem. EN0050M corrected. | |
| Solution: | Download and apply correction
EN221CE207.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE207.LOG
for verification of success. The fix is loaded into library EN member EN0050M. (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old member but copy it as described. To view the Technical Note you will need Adobe Acrobat Reader (see Downloads for free download from Adobe's Website). |
|
| EN221CE208 | Description: | LDA lines longer than 100 bytes are truncated with NATURAL 4.1 |
| Cause: | Limit of NATURAL 2 & 3. EN1011M, EN1012M, EN1014M and EN1031M corrected. | |
| Solution: | Download and apply correction
EN221CE208.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE208.LOG
for verification of success. The fix is loaded into library EN members EN1011M, EN1012M, EN1014M and EN1031M. (1) Copy the existing members to any library not used by E/NAT (2) Load the members to library EN using the ENIFIX utility and (3) distribute the new modules to all libraries EN in all FUSERs used. Note: Do not rename the old members but copy them as described. To view the Technical Note you will need Adobe Acrobat Reader (see Downloads for free download from Adobe's Website). |
|
| EN221011 | Description: | Support Global Type Sequencing with Endevor r7. |
| Cause: | Panel adapted. | |
| Solution: | Download and apply correction EN221011.ZIP. This correction applies to E/NAT 2.2.1 only. | |
| EN221CE209 | Description: |
References to Subroutines not deleted in target environment during
GENERATE / MOVE. This causes problems with NATURAL 4 and steplib
processing (not searched, resulting in NAT0082). Deletion of object is now done using UNCAT command. |
| Cause: | Coding problem. EN1014M corrected. | |
| Solution: | Download and apply correction
EN221CE209.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE209.LOG
for verification of success. The fix is loaded into library EN member EN0050M. (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old member but copy it as described. To view the Technical Note you will need Adobe Acrobat Reader (see Downloads for free download from Adobe's Website). |
|
| EN221CE210 | Description: | Long PREDICT member names (>10 chars) are truncated in case option Include PREDICT XREF is set to “F” on ADD panel. Resulting in I0906 message. |
| Cause: | Coding problem. EN0190M corrected. | |
| Solution: | Download and apply correction
EN221CE210.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE210.LOG
for verification of success. The fix is loaded into library EN member EN0050M. (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old member but copy it as described. To view the Technical Note you will need Adobe Acrobat Reader (see Downloads for free download from Adobe's Website). |
|
| EN221CE211 | Description: | Prevent from adding duplicate Element names for the same member name. |
| Cause: | Coding problem. EN8920M corrected. | |
| Solution: | Download and apply correction
EN221CE211.ZIP
(zipped, see above). This correction applies to E/NAT 2.2.1. Please
download Technical
Note 006 to see how to use the ENIFIX utility provided with E/NAT.
Download and read the text file EN221CE211.LOG
for verification of success. The fix is loaded into library EN member EN0050M. (1) Copy the existing member to any library not used by E/NAT (2) Load the member to library EN using the ENIFIX utility and (3) distribute the new module to all libraries EN in all FUSERs used. Note: Do not rename the old member but copy it as described. To view the Technical Note you will need Adobe Acrobat Reader (see Downloads for free download from Adobe's Website). |
|
| EN221012 | Description: | Accept NATURAL RC1 in E/NAT exit for non-NATURAL types. Suppress NAT9987 message. |
| Cause: | Different RC message handling in NATURAL. | |
| Solution: | Download and apply correction EN221012u.txt. This correction applies to E/NAT 2.2.1 only. | |